Qualität 1898200T M4 Straightshot Mikrodebrider und Handstück zur Reparatur Fabrik

1898200T M4 Straightshot Mikrodebrider und Handstück zur Reparatur

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal ...
Qualität Flexible Endoskop Reparaturtraining für Olympus 260er Serie Fabrik

Flexible Endoskop Reparaturtraining für Olympus 260er Serie

Detail Repair Training For Flexible Endoscope Training Detail 1.Learn about the types of OLYMPUS flexible endoscope, the names of their components and processor, etc. 2.Common Faults and Solutions for 260 series endoscopes 3.Detection steps and practice for 290 series endoscopes 4.Disassemble the ...
Qualität SonoScape EG-500 Elektronische Gastroskopie zur Reparatur Fabrik

SonoScape EG-500 Elektronische Gastroskopie zur Reparatur

SonoScape EG-500 Electronic Gastroscopy For Repair ► Brief Description Inspection Results: 1. No image display, CMOS water ingress fault; 2. 20% of the light bundle is broken; 3. There are bite marks on the insertion tube in multiple places; 4. The biopsy tube is worn out and not smooth; 5. The ...
Qualität Olympus ShockPULSE-SE Lithotripsy Handstück SPL-T zur Reparatur Fabrik

Olympus ShockPULSE-SE Lithotripsy Handstück SPL-T zur Reparatur

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair ► Brief Description Fault: 1.No ultrasonic energy output. Ultrasonic crystal is damaged. Solution: Replace the ultrasonic crystal. ►Problem & Solutoin Brand Olympus Model SPL-T Ultrasonic crystal Damaged Fault No ultrasonic energy output ...
Qualität OLYMPUS OTV-S6H-1D Kamerakopf zur Reparatur Fabrik

OLYMPUS OTV-S6H-1D Kamerakopf zur Reparatur

Olympus OTV-S6H-1D Camera Head For Repair ► Brief Description Fault: 1.Image yes. 2.Cable aging and interference Solution: Replace new cable. ►Problem & Solutoin Brand Olympus Model OTV-S6H-1D Fault Cable aging and interference Solution Replace cable ► Applications Laparoscopy (abdominal surgery) ...
Qualität S5-1 Sektor-Array-Ultraschallsonde zur Reparatur Fabrik

S5-1 Sektor-Array-Ultraschallsonde zur Reparatur

S5-1 sector array ultrasound probe for repair ► Brief Description Fault: Array element aging, lens bubble. Solution: Replace Crystal. ►Problem & Solutoin ModelS5-1FaultArray element aging, lens bubbleSolutionReplace Crystal ► Common issues with S5-1 Probe Image Dropouts / Dead ElementsAcoustic Lens ...
Qualität OLYMPUS CF-H180AL Elektronisches Koloskop zur Reparatur Fabrik

OLYMPUS CF-H180AL Elektronisches Koloskop zur Reparatur

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...
Qualität OLYMPUS TJF-Q180V Elektronisches Duodenoskop zur Reparatur Fabrik

OLYMPUS TJF-Q180V Elektronisches Duodenoskop zur Reparatur

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...
Qualität Aloka UST-5413 Linear Array Ultraschallsonde zur Reparatur Fabrik

Aloka UST-5413 Linear Array Ultraschallsonde zur Reparatur

Aloka UST-5413 linear array ultrasound probe for repair ► Brief Description Fault: Lens break. Solution: Replace lens. ►Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens ► Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConne...
Qualität Ultrasonix EC9-5/10 Endohautensonde zur Reparatur Fabrik

Ultrasonix EC9-5/10 Endohautensonde zur Reparatur

Ultrasonix EC9-5/10 Endo-cavitary probe for repair ► Brief Description Fault: Bad array element. Solution: Replace crystal and housing. ►Problem & Solutoin BrandUltrasonix ModelEC9-5/10FaultBad array elementSolutionReplace crystal and housing ► Common issues with EC9-5/10 Probe Image Dropouts or ...
Qualität GE 4D3C-L 4D Konvex-Schallkopf für Reparatur Fabrik

GE 4D3C-L 4D Konvex-Schallkopf für Reparatur

GE 4D3C-L 4D Convex Transducer For Repair ► Brief Description Fault: 1.Probe dome abrasion & leakage, 2. Dome tube damaged, 3. 4D function not work, 4. Electric motor damaged. Solution:Replace the dome, dome tube; repair electric motor. ►Problem & Solutoin BrandGEModel4D3C-LFault1.Probe dome ...
Qualität PENTAX Medical EPK-i7000 Videoprozessor zur Reparatur Fabrik

PENTAX Medical EPK-i7000 Videoprozessor zur Reparatur

PENTAX Medical EPK-i7000 Video Processor For Repair ► Brief Description Brand: PENTAX (PENTAX Endoscope Processor) Model: EPK-i7000 Serial Number: AC*** Fault: It cannot recognize the endoscope and reports an error. Solution: Repair the system board. Repair Time: 3-5 working days. Warranty Period: ...
Qualität S5-2 Herzsonde für Reparatur Fabrik

S5-2 Herzsonde für Reparatur

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain ...
Qualität L15-7io Lineare Sonde zur Reparatur Fabrik

L15-7io Lineare Sonde zur Reparatur

L15-7io Linear probe for repair ► Brief Description Fault: Lens problem. Solution: Replace probe lens. ►Problem & Solutoin Model L15-7io Fault Lens problem Solution Replace probe lens ► Common issues with L15-7io probe Cable and Connector Issues Acoustic Lens Damage Crystal/Element Failure Housing...
Qualität C5-1 konvexe Sonde zur Reparatur Fabrik

C5-1 konvexe Sonde zur Reparatur

C5-1 convex probe for repair ► Brief Description Fault:Lens problem, cable broken, without strain relief. Solution:Replace probe lens, replace a new cable, replace strain relief. ►Problem & Solutoin Model C5-1 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, ...
Qualität EPlQ/X5-1 2D-Bild der Sonde abnormal zur Reparatur Fabrik

EPlQ/X5-1 2D-Bild der Sonde abnormal zur Reparatur

EPlQ/X5-1 Probe For Repair ► Brief Description Fault: 2D image abnormal Solution: Replace scanhead ►Problem & Solutoin Model EPlQ/X5-1 Fault 2D image abnormal Solution Replace scanhead ► Common Problems & Symptoms Image Artifacts (black lines, dropouts, flickering) → Damaged elements or cable No ...
Qualität C5-2 Konvexsonde für Reparatur von medizinischen Geräten Fabrik

C5-2 Konvexsonde für Reparatur von medizinischen Geräten

C5-2 Convex Probe For Repair ► Brief Description Fault: Strain relief damage, cable broken. Solution: Replace strain relief, repair cable. ►Problem & Solutoin Model C5-2 Convex Fault Strain relief damage, cable broken Solution Replace strain relief, repair cable ► Common Issues with C5-2 Probes Dead ...
Qualität L12-5 lineare Ultraschallsonde zur Reparatur Fabrik

L12-5 lineare Ultraschallsonde zur Reparatur

L12-5 linear array ultrasound probe for repair ► Brief Description Fault: Crystal damage. Solution: Replace crystal. ►Problem & Solutoin Model L12-5 Fault Crystal damage Solution Replace crystal ► Common issues with L12-5 Probe Image Dropouts / Dead Elements Acoustic Lens Damage Cable Damage ...
Qualität L12-3 lineare Sonde zur Reparatur Fabrik

L12-3 lineare Sonde zur Reparatur

L12-3 linear Probe for repair ► Brief Description Fault: Array element aging, lens bubble. Solution: Replace Crystal. ►Problem & Solutoin Model L12-3 Fault Array element aging, lens bubble Solution Replace Crystal ► Common issues with L12-3 Probe Image Dropout: Shadows Dual Images Cable Jacket ...
Qualität L12-3 Ultraschallsonde zur Reparatur Fabrik

L12-3 Ultraschallsonde zur Reparatur

L12-3 Ultrasuound probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens. ►Problem & Solutoin Model L12-3 Fault Lens problem Solution Replace lens ► Common issues with L12-3 Probe Image Dropout: Shadows Dual Images Cable Jacket Damage Connector Damage Strain Relief ...
Qualität Reparatur von medizinischen Geräten Hülsen Stryker 30o 0502-503-030 Laproskop zur Reparatur Fabrik

Reparatur von medizinischen Geräten Hülsen Stryker 30o 0502-503-030 Laproskop zur Reparatur

Stryker 30º 0502-503-030 laproscope, SN:103**** Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. Repair cost: $*** Common Issues with the Stryker ...
Qualität Arthroskop zur Reparatur von Medizinprodukten Fabrik

Arthroskop zur Reparatur von Medizinprodukten

LINVATEC HD 4300 Arthroscope for repair, SN: 62**** Fault: Image with black shadow; eyepiece with scratches, inner optical parts broken. Replace objective lens, inner optical parts, clean and adjust optical system, seal with eyepiece. Image Quality Related Issues: 1.Fogging or Blurry Vision: This is ...
Qualität FUJINON EG-530N Gastroskop zur Reparatur Fabrik

FUJINON EG-530N Gastroskop zur Reparatur

FUJINON EG-530N gastroscope for repair ► Brief Description Fault: 1.Biopsy tube broken; 2.Angle is not enough; 3.Camera over-heating, there are occasional snowflakes on the image and big risk for CCD; 4.Insert tube aging and wrinkle; 5.Light guide tube aging and wrinkle; 6.Stress boot of light guide ...
Qualität Olympus A4674A Autoklavierbares Hysteroskop zur Reparatur Fabrik

Olympus A4674A Autoklavierbares Hysteroskop zur Reparatur

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the ...