logo
Found 90 products for "

camera service

"
Qualität Olympus CF-Q160AL Kolonoskop zur Reparatur Fabrik

Olympus CF-Q160AL Kolonoskop zur Reparatur

Olympus CF-Q160AL scope for repair ► Brief Description Fault: 1.No image, CCD broken; 2.image broken completely; 3.insert tube aging; 4.biopsy tube abrasion; 5.bending section abrasion; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert ...

Qualität Olympus CF-2T160L Koloskop zur Reparatur Fabrik

Olympus CF-2T160L Koloskop zur Reparatur

Olympus CF-2T160L Colonoscope for repair ► Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. Solution: Replace image bundle; insert tube; biopsy ...

Qualität Olympus CF-240AI Koloskop zur Reparatur Fabrik

Olympus CF-240AI Koloskop zur Reparatur

Olympus CF-240AI Colonoscope for repair ► Brief Description Fault: Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. Solution: Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending ...

Qualität Olympus CYF V2 Zystoskop zur Reparatur Fabrik

Olympus CYF V2 Zystoskop zur Reparatur

Olympus CYF V2 Cystoscope For Repair ► Brief Description Fault: Leakage. Solution: Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber. ►Problem & Solutoin Brand Olympus Model CYF V2 Fault Leakage Solution Replace the insert tube, light bundle, biopsy ...

Qualität GIF-XQ240 Gastroskop von Olympus zur Reparatur Fabrik

GIF-XQ240 Gastroskop von Olympus zur Reparatur

GIF-XQ240 Gastroscope by Olympus for repair ► Brief Description Fault: Leakage. Solution: Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ►Problem & Solutoin Brand Olympus Model GIF-XQ240 Fault Leakage. Solution Replace light guide tube,NO.1 button,wire,mesh,adjust angle. ► Common ...

Qualität OLYMPUS TJF-Q180V Elektronisches Duodenoskop zur Reparatur Fabrik

OLYMPUS TJF-Q180V Elektronisches Duodenoskop zur Reparatur

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix ...

Qualität Reparaturwerkzeuge für Ethicon Harmonische Handstück HP054 Langlebig Fabrik

Reparaturwerkzeuge für Ethicon Harmonische Handstück HP054 Langlebig

Repair Tools for Ethicon Harmonic Hand Piece HP054 Product Description 1. Introduction Repair Tools for Ethicon Harmonic Hand Piece HP054 Brand-new REF:HP054 Hand Piece compatible with HAR23, HAR36, HARH23, HARH36,HARH45, HBCO5, HC325,HDHO5 2. Characteristics and Advantages Features: Durable, ...

Qualität Cf-H290i Olympus Kolonoskop Ccd Objektivlinsen Teile eines flexiblen Endoskops Fabrik

Cf-H290i Olympus Kolonoskop Ccd Objektivlinsen Teile eines flexiblen Endoskops

Detail CCD Objective lens for Olympus CF-H290I Colonoscope Spare parts for Olympus GIF-HQ290,GIF-H290,GIF-100,GIF-130,GIF-140,GIF-160 ,GIF-H260,GIF-Q160,GIF-Q180,GIF-Q260 ,GIF-Q30,GIF-V,GIF-V2,GIF-V70,GIF-XQ140,GIF-XQ20,GIF-XQ230,GIF-XQ240,GIF-XQ260,GIF-XP260,GIF-Q260//CF-HQ290I,CF-140,CF-140I,CF...

Qualität Original Distalkopf für Olympus GIF-HQ290 Gastroskopteile Fabrik

Original Distalkopf für Olympus GIF-HQ290 Gastroskopteile

Distal Head for Olympus GIF-HQ290 Gastroscope Parts Spare parts for flexible endoscope: insert tube, light guide tube, light bundle,forcep tube, bending section, rubber, air&water tube, CCD, light source, processor, monitor, etc. Spare parts for Ultrasound system: power supply, probe(Lens, strain ...

Vorherige Nächste
Vorherige
Seite 10 of 10
Nächste