Qualität Olympus CHF-P20Q Endoskop zur Reparatur Fabrik

Olympus CHF-P20Q Endoskop zur Reparatur

Olympus CHF-P20Q endoscope for repair ► Brief Description Fault: 1.Insert tube cracked; 2.Rubber leakage; 3.Image with black point and cracked; 4.Angulation tight; 5.Biopsy tube aging Solution: Replace image bundle; insert tube; biopsy tube; bending mesh and wires; coil pipe; rubber ►Problem & ...

Qualität Olympus CF-Q160AL Kolonoskop zur Reparatur Fabrik

Olympus CF-Q160AL Kolonoskop zur Reparatur

Olympus CF-Q160AL scope for repair ► Brief Description Fault: 1.No image, CCD broken; 2.image broken completely; 3.insert tube aging; 4.biopsy tube abrasion; 5.bending section abrasion; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert ...

Qualität Olympus CF-240AI Koloskop zur Reparatur Fabrik

Olympus CF-240AI Koloskop zur Reparatur

Olympus CF-240AI Colonoscope for repair ► Brief Description Fault: Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. Solution: Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending ...

Qualität Reparierte Olympus-Medizintechnik ist die ultimative Lösung für medizinische Dienstleistungen Fabrik

Reparierte Olympus-Medizintechnik ist die ultimative Lösung für medizinische Dienstleistungen

Product Description: Product Summary: The Medical Device Repair Cases product offered is a comprehensive solution for repairing and maintaining Olympus medical devices. With a warranty of 90 days, customers can have peace of mind knowing that their repaired devices are covered for an extended period...

Qualität Olympus ENF-GP Fiber-Nasopharyngolaryngoskop zur Reparatur Fabrik

Olympus ENF-GP Fiber-Nasopharyngolaryngoskop zur Reparatur

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; ...

Qualität Olympus GIF-Q150 Gastroskop zur Reparatur Fabrik

Olympus GIF-Q150 Gastroskop zur Reparatur

Olympus GIF-Q150 Gastroscope for repair ► Brief Description Fault: 1. With image; 2. Light bundlebreak badly; 3. Insert tubeaging; 4. Biopsy tubeabrasion, leakage badly; 5. Angle tied, bendingsection, wires and helix tube abrasion; 6. Rubberwithout glue. Solution: Replace light bundle, insert tube, ...

Qualität Olympus CF-2T160L Koloskop zur Reparatur Fabrik

Olympus CF-2T160L Koloskop zur Reparatur

Olympus CF-2T160L Colonoscope for repair ► Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. Solution: Replace image bundle; insert tube; biopsy ...

Qualität KARL STORZ 11278A1 Ureteroskop zur Reparatur Fabrik

KARL STORZ 11278A1 Ureteroskop zur Reparatur

KARL STORZ 11278A1 ureteroscope for repair ► Brief Description Fault: 1) Image spotted with partially black point, image bundle aged 2) Light bundle partially wire broken 3) Insert tube aged 4) Biopsy tube abrasion and leakage 5) Wires and coil pipe abrasion Solution: Replace HD image bundle, light ...

Qualität Insighters IS3-F-Laryngoskop zur Reparatur Fabrik

Insighters IS3-F-Laryngoskop zur Reparatur

Insighters IS3-F laryngoscope for repair ► Brief Description Fault: 1. Image blank screen; 2. Insert tube abrasion 3. Bending section transformation; 4. Distal head transformation; Solution: Replace CCD, insert tube, bending section, rubber ►Problem & Solutoin Brand Insighters Model IS3-F Fault 1. ...