logo
Found 90 products for "

objective lens

"
Qualität Lichtleitlinse für Olympus BF-P290 EVIS LUCERA ELITE Video Bronchoskop Fabrik

Lichtleitlinse für Olympus BF-P290 EVIS LUCERA ELITE Video Bronchoskop

Light Guide Lens For Olympus BF-P290 EVIS LUCERA ELITE Video Bronchoscope ► Brief Description The Olympus BF-P290 is an advanced video bronchoscope designed to enhance diagnostic and therapeutic procedures in the respiratory system. ► Features High-Quality Imaging Narrow Band Imaging (NBI) Ultra-Slim Design 2.0 mm Instrument Channel Wide Angulation Range Insertion Tube Rotation Function One-Touch Waterproof Connector Compatibility with EVIS LUCERA ELITE System ► Specification

Qualität Storz Wolf Rod Linsen starres Endoskop Teile auf Lager Fabrik

Storz Wolf Rod Linsen starres Endoskop Teile auf Lager

Detail Rod Lens: Brand Size(4mm) Storz 2.76*29 Stryker 2.68*21 Olympus 2.76*21.4 Wolf 2.76*274MM, 10MM all provided. Spare parts for Rigid Endoscope: Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover, Outer tube & Inner tube,Fiber,etc. More information just feel free to contact us. Guangzhou Care techonoly Co., Ltd. is a company dedicated to the supply of medical equipment maintenance tools, maintenance accessories, professional maintenance training and maintenance

Qualität Karl Storz 27005BA Endoskop zur Reparatur Fabrik

Karl Storz 27005BA Endoskop zur Reparatur

Karl Storz 27005BA endoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualität Olympus GIF-H170 Gastroskop zur Reparatur Fabrik

Olympus GIF-H170 Gastroskop zur Reparatur

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube abrasion. 6. Light guide tube aging and wrinkle. Solution: Replace objective lens, light bundle, small lens, insert tube, biopsy tube, wires, helix tube, light guide tube and rubber.

Qualität Olympus A70940A Autoklavierbares Arthroskop zur Reparatur Fabrik

Olympus A70940A Autoklavierbares Arthroskop zur Reparatur

Olympus A70940A Autoclavable Arthroscope for repair ► Brief Description Fault: 1. Image blur, black dots and dark. 2. Fiber not light enough. 3. Rod lens broken. 4. Objective lens broken and dirty. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model

Qualität Karl Storz 27005BA Cystoscope for repair Fabrik

Karl Storz 27005BA Cystoscope for repair

Karl Storz 27005BA Cystoscope for repair ► Brief Description Fault: 1. No image. 2. Fiber abrasion. 3. Rod lens broken and cracked. 4. Objective lens broken and dirty. 5. Eyepiece cover broken. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Replace eyepiece cover. 8. Clean and install the optical path, check the image. 9. Seal with endoscope and test. ►Problem & Solutoin

Qualität Olympus CF-240L Kolonoskop zur Reparatur Fabrik

Olympus CF-240L Kolonoskop zur Reparatur

Olympus CF-240L Colonoscope for repair ► Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens, C cover. Adjust the angle. ►Problem & Solutoin Brand Olympus Model CF-240L Fault Leakage, glass of light bundle blur, rubber leak, angle not enough, image fuzzle,objective lens scratch, Solution Replace rubber, objective lens, C cover. Adjust the angle. ► Common

Qualität Stryker 30º 0502-503-030 laproscope for repair Fabrik

Stryker 30º 0502-503-030 laproscope for repair

Stryker 30º 0502-503-030 laproscope for repair ► Brief Description Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. ►Problem & Solutoin Brand Stryker Model 0502-503-030 Fault Image blur, objective lens loose without glue, inner optical parts broken. Solution Add glue for objective lens, replace inner optical parts, clean and

Qualität Olympus A4674A Autoklavierbares Hysteroskop zur Reparatur Fabrik

Olympus A4674A Autoklavierbares Hysteroskop zur Reparatur

Olympus A4674A Autoclavable Hysteroscope for repair ► Brief Description Fault: 1. Image blur and black shadow. 2. Rod lens broken. 3. Outer tube bending and transformation. Solution: 1. Replace rod lens. 2. Replace inner tube. 3. Replace outer tube. 4. Replace objective lens group. 5. Clean the eyepiece. 6. Replace fiber. 7. Clean and install the optical path, check the image. 8. Seal with endoscope and test. ►Problem & Solutoin Brand Olympus Model A4674A Fault 1. Image blur