Qualität Aloka UST-5413 Linear Array Ultraschallsonde zur Reparatur Fabrik

Aloka UST-5413 Linear Array Ultraschallsonde zur Reparatur

Aloka UST-5413 linear array ultrasound probe for repair ► Brief Description Fault: Lens break. Solution: Replace lens. ►Problem & Solutoin BrandAlokaModelUST-5413FaultLens breakSolutionReplace lens ► Common issues with UST-5413 Probe Image dropouts or black linesAcoustic lens damageCable damageConne...

Qualität Olympus CF-240L Kolonoskop zur Reparatur Fabrik

Olympus CF-240L Kolonoskop zur Reparatur

Olympus CF-240L Colonoscope for repair ► Brief Description Fault: Leakage, glass of light bundle blur, rubber leak, angle not enough,image fuzzle,objective lens scratch. Solution: Replace rubber, objective lens, C cover. Adjust the angle. ►Problem & Solutoin Brand Olympus Model CF-240L Fault Leakage...

Qualität Olympus CF-H190L Kolonoskop zur Reparatur Fabrik

Olympus CF-H190L Kolonoskop zur Reparatur

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

Qualität Olympus GIF-Q180 Gastroskop zur Reparatur Fabrik

Olympus GIF-Q180 Gastroskop zur Reparatur

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

Qualität Olympus GIF-1TQ160 Gastroskop zur Reparatur Fabrik

Olympus GIF-1TQ160 Gastroskop zur Reparatur

Olympus GIF-1TQ160 gastroscope for repair ► Brief Description Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. Solution: Replace CCD, ...

Qualität Olympus CF-Q160AL Kolonoskop zur Reparatur Fabrik

Olympus CF-Q160AL Kolonoskop zur Reparatur

Olympus CF-Q160AL scope for repair ► Brief Description Fault: 1.No image, CCD broken; 2.image broken completely; 3.insert tube aging; 4.biopsy tube abrasion; 5.bending section abrasion; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, light bundle, insert ...

Qualität Olympus CF-2T160L Koloskop zur Reparatur Fabrik

Olympus CF-2T160L Koloskop zur Reparatur

Olympus CF-2T160L Colonoscope for repair ► Brief Description Fault: 1. With image. 2. 10% light bundle broken. 3. Insert tube is ok. 4. Biopsy tube abrasion. 5. Angle tied, bending section transformation. 6. Wires, helix tube abrasion, no up angle. Solution: Replace image bundle; insert tube; biopsy ...

Qualität Olympus CF-240AI Koloskop zur Reparatur Fabrik

Olympus CF-240AI Koloskop zur Reparatur

Olympus CF-240AI Colonoscope for repair ► Brief Description Fault: Image blur,insert tube aging,light guide squashed,light guide broken 50%,nozzle blocked,angle tight,forceps channel aging. Solution: Replace insertion tube,CCD chips,light guide,forceps channel,water channel,angulation wire,bending ...

Qualität Olympus CYF V2 Zystoskop zur Reparatur Fabrik

Olympus CYF V2 Zystoskop zur Reparatur

Olympus CYF V2 Cystoscope For Repair ► Brief Description Fault: Leakage. Solution: Replace the insert tube, light bundle, biopsy channel, bending section, wire, steel mesh, rubber. ►Problem & Solutoin Brand Olympus Model CYF V2 Fault Leakage Solution Replace the insert tube, light bundle, biopsy ...