logo
Found 90 products for "

camera repair service

"
Qualität Hochwertiger Staubschutz für OLYMPUS/ WOLF/STORZ/Stryker/Smith&Nephew/CONMED Kamerakopf Fabrik

Hochwertiger Staubschutz für OLYMPUS/ WOLF/STORZ/Stryker/Smith&Nephew/CONMED Kamerakopf

High Quality Dust Shield For OLYMPUS/ WOLF/STORZ/Stryker/CONMED Camera Head ► Brief Description In a surgical setting, it is a standard "best practice" to never leave a camera head uncovered. If the endoscope is removed, the dust cap should be applied immediately to prevent "fogging" or contamination from the operating room environment.the parameters and functions are centered around maintaining optical sterility and mechanical integrity. ► Features Sensor & Lens Protecti

Qualität Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip Kamerakopf Fabrik

Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip Kamerakopf

Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip Camera Head ► Brief Description The Richard Wolf 85525922 is a professional-grade ENDOCAM Logic HD 3-Chip Camera Head. It is designed for high-end endoscopic imaging, offering superior color reproduction and clarity through its triple-sensor technology.It is a high-performance imaging component designed for minimally invasive surgery ,used in various surgical disciplines (Laparoscopy, Arthroscopy, etc.) to provide high-definition

Qualität Hochwertiges CCD für KARL STORZ H3-Z Kamera Fabrik

Hochwertiges CCD für KARL STORZ H3-Z Kamera

High Quality CCD For KARL STORZ H3-Z Camera Head ► Brief Description The KARL STORZ H3-Z camera head is a cornerstone component of the IMAGE1 HD endoscopy system. It utilizes advanced sensor technology to deliver high-resolution images for surgical procedures. ► Features High-Resolution Image Capture Parfocal Optical Zoom Control Progressive Scanning Real-Time Image Transmission Automatic Light/Exposure Management Programmable Remote Control Accurate Color Reproduction ►

Qualität Hochwertiger CCD für KARL STORZ H3 Kamerakopf Fabrik

Hochwertiger CCD für KARL STORZ H3 Kamerakopf

High Quality CCD For KARL STORZ H3 Camera Head ► Brief Description The function of the CCD (Charge-Coupled Device) component within the STORZ H3 Camera Head is fundamental to its operation.The CCD acts as the image sensor, converting the light captured by the endoscope/lens into an electrical signal that can be processed and displayed as an image. ► Features Light-to-Signal Conversion (Image Sensing) Color Separation and Fidelity High Resolution Image Generation Low Noise and

Qualität Reparatur von medizinischen Geräten Hülsen Stryker 30o 0502-503-030 Laproskop zur Reparatur Fabrik

Reparatur von medizinischen Geräten Hülsen Stryker 30o 0502-503-030 Laproskop zur Reparatur

Stryker 30º 0502-503-030 laproscope, SN:103**** Fault: Image blur, objective lens loose without glue, inner optical parts broken. Solution: Add glue for objective lens, replace inner optical parts, clean and adjust optical system, seal with eyepiece. Repair cost: $*** Common Issues with the Stryker 0502-503-030 Laparoscope: 1.Fogging/Obscured Vision: This is a frequent issue during laparoscopic procedures. It can be caused by temperature differences between the endoscope and

Qualität Kabel für die Stryker 1288HD-Kamera Fabrik

Kabel für die Stryker 1288HD-Kamera

Power Camera Cable for Stryker 1288HD Camera Head Brand: Stryker Model: 1288HD Series: Camera Cable Use for Stryker 1288HD Camera Head If you have any questions about Stryker 1288HD Camera Head , please feel free to contact us. CareUtech is a global provider of medical equipment and medical equipment repair services, as well as medical equipment repair training services, mainly focusing on ultrasound machines and transducers, flexible and rigid endoscopes, camera system,

Qualität STORZ 1HD H3-ZA 22220061 Autoklavierbares Kamera-Kopf TH104 Kabel Fabrik

STORZ 1HD H3-ZA 22220061 Autoklavierbares Kamera-Kopf TH104 Kabel

Storz 1HD H3-ZA 22220061 / TH104 Autoclavable Camera Cable Brand: Storz Model: H3-ZA 22220061 Series: Camera Cable Use for Karl Storz Image 1 Spies HD Camera Head H3-ZA TH104 TH-104 If you have any questions about 1HD H3-ZA Autoclavable Camera Cable 22220061 for Storz, please feel free to contact us. CareUtech is a global provider of medical equipment and medical equipment repair services, as well as medical equipment repair training services, mainly focusing on ultrasound

Qualität Reparatur von medizinischen Geräten Fabrik

Reparatur von medizinischen Geräten

GE RIC5-9-D Probe Fault: Dome loose, straight relief tiny broken, with error on machine. Solution: Replace dome and oiling. Repair cost : $***. Common Issues with the GE RIC5-9-D Ultrasound Probe: Image Artifacts/Dropouts: These can manifest as lines, shadowing, or a complete loss of image in certain areas. Common causes include: Crystal Damage: Piezoelectric crystals within the transducer array can become damaged due to physical impact, overheating, or degradation over time.

Qualität OLYMPUS CF-HQ190L Reparaturgehäuse für medizinische Geräte Fabrik

OLYMPUS CF-HQ190L Reparaturgehäuse für medizinische Geräte

OLYMPUS CF-HQ190L Repair Problem: 1, Image display;2, Light bundle broken about 10%;3, Insertion tube is ok;4, Biospy channel worn and leaking;5, The upper angle broken, helix tube and bending section were worn;6, Light guide tube indented and the back cover is leaking;7, The EL-connector is not good sealed and leaking. Solution: Replace biopsy channel, bending section, wire, helix tube, light guide tube, rubber Company Profile Guangzhou Careutech Co., Ltd. supplies medical